Intraocular pressure following peritomy and wet-field coagulation.
Kyoo Won Lee
Department of Ophthalmology, College of Medicine, Yeungnam University, Daegu, Korea.
Abstract
The changes in intraocular pressure (IOP) following peritomy and wet-field coagulation of 10 rabbit eyes and 7 human cataractous eyes were investigated. The IOP difference before and after 180-degree and 360-degree wet-field coagulation on rabbit eyes showed an average increase of 11.0 +/- 5.8 mmHg and 25.8 +/- 7.1 mmHg(mean +/- SD), respectively (p < 0.05, p < 0.01). The IOP of both groups in rabbit eyes were elevated for 2 to 3 days postoperatively and then became normal by the 7th postoperative day. The IOP difference before and after 180-degree peritomy and wet-field coagulation in human cataractous eyes showed an average increase of 8.4 +/- 5.8 mmHg(mean +/- SD)(p < 0.05). The outflow facility was poor immediately following wet-field coagulation but then improved gradually by means of tonography and concentration changes of anterior chamber neutral-red. Histologically, there was endothelial cell damage, congestion, and red blood cell extravasation of the episcleral and intrascleral vessels at one day after wet-field coagulation in the light microscopic findings. Recanalization of the episcleral and intrascleral capillaries was noted 3 days after wet-field coagulation and was completed 3 weeks after wet-field coagulation. There was poor plastic infusion through the trabecular spaces in the one-day postoperative group compared to the control group by scanning electron micrograph. In conclusion, we have to bear in mind the possibility of an IOP rise after wet-field coagulation following peritomy for cataract and retinal surgery.
Key Words: intraocular pressure;peritomy;wet-field coagulation;tonography;neutralred;scanning electon microscopy (SEM);light microscopy
TOOLS
METRICS Graph View
  • 1 Crossref
  • 2 Scopus
  • 1,162 View
  • 5 Download
Related articles

Intraocular pressure and axial length in children.1990 June;4(1)



ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next