Korean J Ophthalmol > Volume 40(4); 2026 > Article
Hong, Hyon, and Jeon: Lens Thickness and Refractive Prediction Error after Cataract Surgery across Age Groups, Including Patients Aged 90 Years or Older

Abstract

Purpose

To investigate the impact of lens thickness (LT) on refractive prediction error (PE) and age-related ocular biometric changes after cataract surgery across age groups, including patients aged 90 years or older.

Methods

This retrospective single-center study included one eligible eye from each of 372 patients who underwent phacoemulsification with a single intraocular lens model and were measured with the IOLMaster 700. Patients were classified into five age groups. PE and absolute prediction error (APE) were evaluated using the Haigis, SRK/T, Hoffer Q, and Barrett Universal II formulas. The association between LT and PE was assessed by dividing eyes at the cohort mean LT of 4.57 mm (an exploratory cutoff). Patients aged ≥90 years were compared with those aged <90 years, and a bilateral-eye analysis accounting for intereye correlation was performed.

Results

Advancing age was associated with shorter axial length (AL) (p = 0.001), shallower anterior chamber depth (ACD), and greater LT (both p < 0.001). Age correlated negatively with AL (r = −0.202) and ACD (r = −0.311) and positively with LT (r = 0.430, all p < 0.001). Patients aged ≥90 years showed greater LT and shallower ACD than those aged <90 years (both p < 0.05), whereas APE did not differ between the two groups. Although APE did not differ among age groups, eyes with greater LT showed larger APEs than those with smaller LT across all formulas (all p < 0.05) and a relative hyperopic shift in adjusted analyses (all p ≤ 0.027). Barrett Universal II showed the lowest APE in the overall cohort.

Conclusions

Advancing age was associated with characteristic ocular biometric changes, particularly evident in patients aged ≥90 years. Greater LT, rather than chronological age, was associated with reduced refractive predictability after cataract surgery and may serve as a practical marker of refractive uncertainty. Barrett Universal II performed best overall.

Cataract remains the leading cause of visual impairment and blindness worldwide, accounting for a substantial proportion of correctable vision loss across all age groups [1]. With the global aging of populations, the number of individuals aged 90 years or older has grown markedly, and this trend is expected to continue in coming decades [2]. Consequently, cataract surgery is increasingly being performed in very elderly patients, a population that presents distinct clinical challenges compared with younger age groups. Previous studies have demonstrated that cataract surgery is generally safe and effective in very elderly patients, with visual outcomes comparable to those achieved in younger populations [3-6].
Accurate prediction of postoperative refractive outcomes is an essential goal of modern cataract surgery and is one of the primary determinants of patient satisfaction. Despite advances in optical biometry and intraocular lens (IOL) power calculation formulas, refractive prediction error (PE) remains a clinically meaningful challenge, particularly in eyes with atypical anatomical configurations [7-13]. Age-related anatomical changes in the anterior segment, including increased lens thickness (LT) and decreased anterior chamber depth (ACD), are well-documented and may alter the accuracy of IOL power calculation by affecting the estimation of effective lens position (ELP), which is one of the most critical variables in modern IOL formulas [14-19]. In particular, increased LT has been reported to be associated with shallower ACD and may adversely influence the prediction of postoperative IOL position, leading to greater refractive PEs [8,18-23].
However, whether age-related anatomical alterations— particularly increased LT, independently of chronological age—contribute to reduced refractive predictability after cataract surgery has not been systematically evaluated [7,22,23]. Moreover, although such changes are expected to be most pronounced in the very elderly, the ocular biometric characteristics of patients aged 90 years or older remain incompletely described, as most prior biometric studies have examined elderly populations broadly without specifically analyzing this age group [14-18,20,21]. Therefore, this study aimed to assess the influence of increased LT on refractive PEs across five age groups and to characterize age-related ocular biometric changes, including an analysis of patients aged 90 years or older.

Materials and Methods

Ethics statement

This study adhered to the tenets of the Declaration of Helsinki and was approved by the Institutional Review Board of Seoul National University Bundang Hospital (No. B-2408-918-107). Informed consent was waived due to the use of deidentified data and the retrospective nature of the study.

Study design and participants

This retrospective study included patients who underwent uneventful phacoemulsification with implantation of a Tecnis ZCB00 IOL (Johnson & Johnson Vision Care Inc.) between March 2019 and June 2021 at a single tertiary center. For the primary analytic cohort, only eyes with available preoperative biometry measured using the IOLMaster 700 were included. Eyes with target refraction more myopic than −1.0 diopters (D) were excluded. Eyes with ocular comorbidities that could affect biometric measurements or postoperative outcomes were excluded, including previous ocular surgery, corneal disease, retinal disease including age-related macular degeneration, glaucoma, and other significant concomitant ophthalmic disorders. Eyes with intraoperative complications, including posterior capsule rupture, anterior vitrectomy, or scleral fixation, were also excluded. In addition, eyes with LT <3.0 mm were considered outliers and excluded from the final analyses. One eye per patient was included to ensure statistical independence. When both eyes were eligible, one eye was randomly selected using a computer-generated procedure. Patients were then categorized into five age groups according to age at the time of surgery: 40-59, 60- 69, 70-79, 80-89, and ≥90 years.
Ocular biometric parameters for the primary analytic cohort were measured using the IOLMaster 700 (Carl Zeiss Meditec). The following parameters were obtained: axial length (AL), flat keratometry (K1), steep keratometry (K2), mean keratometry (Km; defined as the average of K1 and K2), ACD, and LT. PE was defined as the postoperative spherical equivalent refraction minus the formula-predicted refraction. Accordingly, negative PE values indicated a myopic error, whereas positive values indicated a hyperopic error. Absolute prediction error (APE) was defined as the absolute value of PE. APE was calculated at 1 month postoperatively using four IOL power calculation formulas: Haigis, SRK/T, Hoffer Q, and Barrett Universal II. Visual acuity (VA) improvement was defined as preoperative best-corrected visual acuity (BCVA) in logMAR units minus postoperative logMAR BCVA. Therefore, a positive value indicated greater postoperative visual improvement.
After applying the exclusion criteria, restricting the cohort to eyes with available IOLMaster 700 biometry, and performing the one-eye selection procedure, 372 eyes of 372 patients were included in the overall analytic cohort. LT was available in all 372 eyes, Km was available in 370 eyes, and VA improvement was available in 364 eyes. Formula- specific analyses were performed using available- case data. For the bilateral-eye sensitivity analysis, 566 eligible eyes from the same 372 patients were included, with patient-level clustering used to account for intereye correlation.

Statistical analysis

Statistical analyses were performed using IBM SPSS ver. 23 (IBM Corp.) and R software ver. 4.4.1 (R Foundation for Statistical Computing). Continuous variables were compared using one-way analysis of variance (ANOVA) with Bonferroni-adjusted post hoc comparisons when significant differences were identified. Categorical variables were compared using the Pearson chi-square test or Fisher exact test, as appropriate. Pearson correlation analysis was used to evaluate the relationships between age and ocular biometric parameters. Multiple linear regression analysis was performed to identify factors independently associated with ACD and LT. In addition to the five-group age analysis, binary comparisons were performed between patients aged ≥90 years and those aged <90 years.
For LT-based subgroup analyses, eyes were divided at the cohort mean LT of 4.57 mm. This cutoff was considered exploratory rather than clinically established. Formula- specific PEs were compared across age and LT groups, and their associations with continuous LT were assessed using multivariable models adjusted for ACD, AL, Km, and age.
To compare APEs among the four IOL power calculation formulas within each age group, Friedman tests were performed using eyes with complete data for all four formulas. When the overall Friedman test was significant, post hoc pairwise comparisons were performed with Bonferroni correction. Bilateral-eye sensitivity analyses used patient- clustered generalized estimating equations. Statistical significance was defined as p < 0.05.

Results

A total of 372 eyes of 372 patients were included in the overall analytic cohort. Table 1 shows baseline characteristics by age group. Older patients had significantly higher rates of general anesthesia and higher prevalence of hypertension and cerebrovascular disease, whereas the prevalence of diabetes mellitus did not differ significantly among age groups. The ≥90-year group comprised 25 patients.
AL, ACD, and LT differed significantly across age groups (Table 1). Older patients showed shorter AL (p = 0.001), shallower ACD (p < 0.001), and greater LT (p < 0.001). Pearson correlation analysis demonstrated that age was significantly negatively correlated with AL (r = −0.202, p < 0.001) and ACD (r = −0.311, p < 0.001), where- as it was significantly positively correlated with LT (r = 0.430, p < 0.001) (Fig. 1A-1C).
VA improvement also differed significantly across age groups (ANOVA p = 0.019) (Table 1). Patients aged 90 years or older showed greater postoperative improvement, which may partly reflect worse baseline VA in this age group. In Bonferroni-adjusted post hoc analysis, the ≥90- year group showed significantly greater VA improvement than the 70- to 79-year group (p = 0.013).
Table 2 shows PE and APE according to age group. PE did not differ significantly across age groups or between the ≥90-year and <90-year groups for any of the four formulas (Haigis, SRK/T, Hoffer Q, and Barrett Universal II; all p > 0.05). APE also did not differ significantly among age groups for any formula. In the overall cohort, Barrett Universal II had the lowest mean APE (0.41 ± 0.47 D). Within-age-group comparisons among the four formulas showed a significant difference only in the 60-69-year group (Friedman test, p < 0.001). In Bonferroni-corrected post hoc analysis, Barrett Universal II showed significantly lower APEs than SRK/T (p = 0.003) and Hoffer Q (p = 0.001), whereas its difference from Haigis was not statistically significant. No significant between-formula differences were observed in the other age groups.
In the binary comparison between patients aged ≥90 years and those aged <90 years, patients aged ≥90 years had shallower ACD (2.88 ± 0.43 mm vs. 3.07 ± 0.43 mm, p = 0.044), greater LT (4.81 ± 0.41 mm vs. 4.55 ± 0.46 mm, p = 0.007), and greater VA improvement (0.82 ± 0.70 log- MAR vs. 0.44 ± 0.58 logMAR, p = 0.019) than patients aged <90 years. AL was numerically shorter in the ≥90- year group but did not reach statistical significance (p = 0.079). Formula-specific PEs and APEs did not differ significantly between the two binary age groups (all p > 0.05) (Tables 1, 2).
In multiple linear regression analysis (Table 3), greater LT was independently associated with shallower ACD (coefficient = −0.504, p < 0.001), whereas longer AL (coefficient = 0.250, p < 0.001) and steeper Km (coefficient = 0.073, p < 0.001) were independently associated with deeper ACD (model 1). Age was not significantly associated with ACD after adjustment for LT and other biometric parameters (p = 0.774). In model 2, in which LT was the dependent variable, older age (coefficient = 0.011, p < 0.001), shallower ACD (coefficient = −0.721, p < 0.001), and longer AL (coefficient = 0.079, p < 0.001) were independently associated with greater LT.
When eyes were divided according to the mean LT of 4.57 mm, eyes with thicker lenses showed significantly larger APEs than those with thinner lenses across all formulas, whereas PEs did not show significant differences between LT groups at any formula except for Haigis. In the thicker-lens group, the mean APEs were 0.52 ± 0.57 D for Haigis, 0.51 ± 0.59 D for SRK/T, 0.54 ± 0.58 D for Hoffer Q, and 0.48 ± 0.58 D for Barrett Universal II, all of which were significantly greater than those in the thinner- lens group (all p < 0.05). Among the formulas, Barrett Universal II showed the lowest APE in both LT groups. These findings suggest that increased LT may adversely affect refractive prediction accuracy regardless of the formula used.
The Haigis formula showed a significantly more positive PE in eyes with LT ≥4.57 mm than in those with LT <4.57 mm (0.038 ± 0.771 D vs. −0.188 ± 0.480 D, p = 0.004), whereas no significant between-group differences were observed for SRK/T, Hoffer Q, or Barrett Universal II (Table 4).
Table 5 shows the proportions of eyes within specified PE ranges according to LT group. In the one-eye analysis, the proportions of eyes within ±0.50 D were consistently lower in the LT ≥4.57 mm group than in the LT <4.57 mm group, but the differences did not reach statistical significance for Haigis (p = 0.050), SRK/T (p = 0.202), Hoffer Q (p = 0.136), or Barrett Universal II (p = 0.109) (Table 5). In the bilateral-eye GEE sensitivity analysis, the thicker-lens group had significantly lower odds of achieving PE within ±0.50 D across all formulas (odds ratio range, 0.60-0.63; all p < 0.05) (Table 5). These sensitivity analyses were consistent with poorer refractive predictability in thicker- lens eyes, although the significant GEE results should be interpreted alongside the nonsignificant one-eye proportion comparisons.
In multivariable analyses adjusted for ACD, AL, Km, and age, greater LT was associated with a more positive PE across all four formulas (adjusted coefficients = 0.312-0.502 D/mm; all p ≤ 0.027), indicating a relative hyperopic shift. In contrast, continuous LT was not significantly associated with APE in any formula after the same adjustment (all p > 0.05). These findings suggest that LT may be associated with the direction of refractive PE, but not with the absolute magnitude of error (Table 6).

Discussion

In this study, advancing age was associated with distinct ocular biometric changes—shorter AL, shallower ACD, and greater LT—that were also evident in patients aged 90 years or older. Among these parameters, LT showed the strongest positive correlation with age, whereas AL and ACD were negatively correlated with age. In multiple regression analysis, older age, shallower ACD, and longer AL were independently associated with greater LT, indicating that age-related anterior segment changes are closely interrelated rather than occurring in isolation. Notably, this increase in LT, rather than chronological age itself, emerged as the parameter most relevant to refractive predictability.
Chronological age itself was not independently associated with greater APE, as refractive accuracy did not differ significantly across the five age groups or between patients aged ≥90 years and those aged <90 years. In contrast, advancing age was strongly associated with increased LT and shallow ACD. In the LT-group comparison, greater LT showed larger APEs across all formulas; however, in multivariable analysis using LT as a continuous variable, LT was significantly associated with a more positive PE, but not with APE. These findings suggest that increased LT may primarily influence the direction of refractive PE, producing a relative hyperopic shift. Therefore, the biometric consequences of aging, particularly increased LT, rather than age per se, may be the more proximate determinant of reduced refractive predictability. Although some prior studies have reported that refractive predictability declines with advancing age after cataract surgery, our results indicate that this decline may be mediated by age-related anterior segment changes, especially increased LT, rather than by chronological age itself [8,22,23].
Previous biometric studies have consistently shown that aging is accompanied by progressive lens thickening and anterior chamber shallowing [14-16]. With advancing age, the crystalline lens thickens because of continuous lens fiber deposition throughout life, leading to anterior displacement of the lens and crowding of the anterior segment [17,18]. These structural changes may affect the estimation of ELP, one of the most important sources of error in modern IOL power calculation, and previous studies have shown that LT and anterior segment configuration are important determinants for predicting postoperative IOL position after cataract surgery [9,18]. Such age-related changes are expected to be most pronounced in the oldest eyes, and additional factors that were not assessed in this study, such as subtle age-related zonular laxity or capsular bag instability, might further increase variability in postoperative IOL position even after otherwise uneventful surgery, although these factors could not be quantified retrospectively.
After cataract extraction, the thick crystalline lens is replaced by a substantially thinner IOL, and the final IOL position depends on postoperative capsular bag and zonular behavior that may not be fully captured by preoperative ACD and LT. Consequently, the relationship between a crowded preoperative anterior segment and the eventual postoperative ELP may be less predictable. Because errors in postoperative IOL position estimation are a major source of refractive PE, even small discrepancies between predicted and actual IOL position may produce clinically meaningful refractive deviations [24]. Formula-specific differences in the use of ACD and LT may further contribute to variation in the magnitude and direction of PE [25]. Prior studies have shown that increased lens vault or a shallow anterior chamber is associated with formula-dependent refractive bias, often toward hyperopic error, and that LT may correlate with refractive PE in such eyes [10,11]. Consistent with these reports, eyes with greater LT in our study showed significantly larger APEs across all formulas. The one-eye proportion analysis showed the same direction of effect without reaching statistical significance at the ±0.50 D threshold, whereas the bilateral-eye GEE sensitivity analysis demonstrated significantly lower odds of achieving PE within ±0.50 D in the thicker-lens group across all formulas. The concordant direction across analyses supports an association between increased LT and reduced refractive predictability, although the difference in statistical significance should be interpreted cautiously.
These findings may have practical implications for preoperative counseling. Biometric features such as greater LT and shallower ACD, rather than chronological age alone, may help identify eyes at increased risk of refractive unpredictability. Patients with a crowded anterior segment may be informed that postoperative refraction could deviate more from the intended target and that spectacle correction may still be required. Although greater LT was associated with a relative hyperopic shift in adjusted analyses, the mean PE was close to zero; therefore, counseling should emphasize reduced predictability rather than a uniform hyperopic outcome.
Among the formulas analyzed, Barrett Universal II showed the smallest mean APE in both LT groups and the highest proportion of eyes within ±0.50 D. This finding is also broadly consistent with previous studies showing that modern formulas such as Barrett Universal II perform relatively well in elderly eyes and in eyes with challenging anterior segment anatomy [8,10,12,21-23]. Unlike traditional formulas such as SRK/T or Hoffer Q, Barrett Universal II incorporates multiple ocular parameters, including ACD, LT, AL, and K, to estimate postoperative ELP using a theoretical model rather than relying primarily on regression- based assumptions [9]. Therefore, in eyes with altered anterior segment anatomy, such as those with increased LT and shallow ACD commonly seen in very elderly patients, the use of multiple biometric parameters may partly explain the favorable performance of Barrett Universal II in the present cohort. Interestingly, direct comparisons among formulas within each age group showed a significant difference only in the 60- to 69-year group, where Barrett Universal II was significantly more accurate than SRK/T and Hoffer Q but not Haigis after multiplicity adjustment. Therefore, the apparent advantage of Barrett Universal II should be interpreted as a favorable overall accuracy profile rather than definitive superiority in every age group.
However, not all previous studies have shown that direct inclusion of LT necessarily improves formula accuracy in unselected cataract populations. Taroni et al. [13] found that incorporation of LT as an optional biometric parameter did not yield a significant improvement in refractive prediction accuracy across the Barrett Universal II, Emmetropia Verifying Optical (EVO), Kane, and Hill-radial basis function formulas in routine cataract cases. This suggests that the clinical relevance of LT may be more pronounced in specific subgroups, such as very elderly patients with marked anterior segment crowding, rather than in routine cataract populations. In the present cohort, the 4.57-mm cutoff represented the cohort mean and was used as an exploratory grouping threshold rather than a validated clinical boundary. Nevertheless, the consistent increase in mean APE among thicker-lens eyes suggests that LT may be useful as a practical marker of refractive uncertainty. Future studies should evaluate continuous LT effects and compare newer formulas, including Kane and EVO, in very elderly and thick-lens eyes.
This study has several limitations. First, its retrospective, single-center design may have introduced selection bias, and the inclusion of multiple surgeons, particularly in patients aged 90 years or older, may have contributed to variability in surgical outcomes. Second, the primary analysis used one randomly selected eye per patient to avoid intereye correlation; although the bilateral-eye GEE sensitivity analysis showed a consistent direction of effect, the differences in statistical significance between the two approaches should be interpreted cautiously. Third, the LT cutoff was based on the cohort mean and remains exploratory rather than a validated threshold. Fourth, subtle zonular weakness and capsular biomechanics were not systematically quantified. Fifth, the subgroup aged ≥90 years was small (25 patients), and formula-specific refractive outcomes were available for even fewer eyes, limiting the statistical power of comparisons involving the very elderly group; accordingly, these results should be regarded as descriptive. Finally, the findings were derived from a single IOL model, four formulas and IOLMaster 700 biometry, which enhanced consistency but may limit generalizability to other IOL types and biometric devices. Moreover, the findings may not extend to newer-generation formulas such as Kane and EVO, which incorporate LT differently and warrant further investigation.
In conclusion, across age groups, advancing age was associated with greater LT and shallower ACD, with these changes particularly evident in patients aged 90 years or older. Increased LT, rather than chronological age itself, was associated with refractive prediction patterns, including larger APEs in LT-group comparisons and a relative hyperopic shift in adjusted analyses. LT may therefore serve as a potential marker of refractive uncertainty. Barrett Universal II showed the lowest mean APE in the overall cohort.

Notes

Conflicts of Interest

None.

Acknowledgements

None.

Funding

This work was supported by a grant funded by the Seoul National University Bundang Hospital (SNUBH) Research Fund (Grant No. 09-2019-0002 [HSJ]), and National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (RS-2026-25482552 [HSJ]). The funding organization had no role in the design or conduct of this research.

References

1. Lin L, Liang Y, Jiang G, et al. Global, regional, and national burden of cataract: a comprehensive analysis and projections from 1990 to 2021. PLoS One 2025;20:e0326263..
crossref pmid pmc
2. Bullain SS, Corrada MM. Dementia in the oldest old. Continuum (Minneap Minn) 2013;19:457-69.
crossref pmid pmc
3. Syam PP, Eleftheriadis H, Casswell AG, et al. Clinical outcome following cataract surgery in very elderly patients. Eye (Lond) 2004;18:59-62.
crossref pmid pdf
4. Toyama T, Ueta T, Yoshitani M, et al. Visual acuity improvement after phacoemulsification cataract surgery in patients aged ≥90 years. BMC Ophthalmol 2018;18:280.
crossref pmid pmc pdf
5. Nussinovitch H, Tsumi E, Tuuminen R, et al. Cataract surgery in very old patients: a case-control study. J Clin Med 2021;10:4658.
crossref pmid pmc
6. Ono T, Fukuda T, Iwasaki T, et al. Outcomes of cataract surgeries performed in 8 eyes of centenarians. Medicine (Baltimore) 2024;103:e39108.
crossref pmid pmc
7. Hayashi K, Ogawa S, Yoshida M, Yoshimura K. Influence of patient age on intraocular lens power prediction error. Am J Ophthalmol 2016;170:232-7.
crossref pmid
8. Melles RB, Holladay JT, Chang WJ. Accuracy of intraocular lens calculation formulas. Ophthalmology 2018;125:169-78.
crossref pmid
9. Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol Scand 2007;85:472-85.
crossref pmid
10. Yan C, Yao K. Effect of lens vault on the accuracy of intraocular lens calculation formulas in shallow anterior chamber eyes. Am J Ophthalmol 2022;233:57-67.
crossref pmid
11. Lee Y, Kim MK, Oh JY, et al. Intraocular lens power calculation in eyes with a shallow anterior chamber depth and normal axial length. PLoS One 2023;18:e0288554.
crossref pmid pmc
12. Mo E, Lin L, Wang J, et al. Clinical accuracy of 6 intraocular lens power calculation formulas in elongated eyes, according to anterior chamber depth. Am J Ophthalmol 2022;233:153-62.
crossref pmid
13. Taroni L, Hoffer KJ, Lupardi E, et al. Accuracy of new intraocular lens power calculation formulas: a lens thickness study. J Refract Surg 2021;37:202-6.
crossref pmid
14. Jonas JB, Iribarren R, Nangia V, et al. Lens position and age: The Central India Eye and Medical Study. Invest Ophthalmol Vis Sci 2015;56:5309-14.
crossref pmid
15. Shammas HJ, Shammas MC. Measuring the cataractous lens. J Cataract Refract Surg 2015;41:1875-9.
crossref pmid
16. Tsorbatzoglou A, Nemeth G, Szell N, et al. Anterior segment changes with age and during accommodation measured with partial coherence interferometry. J Cataract Refract Surg 2007;33:1597-601.
crossref pmid
17. Tripathi RC, Tripathi BJ. Lens morphology, aging, and cataract. J Gerontol 1983;38:258-70.
crossref pmid
18. Satou T, Shimizu K, Tsunehiro S, et al. Relationship between crystalline lens thickness and shape and the identification of anterior ocular segment parameters for predicting the intraocular lens position after cataract surgery. Biomed Res Int 2019;2019:3458548.
crossref pmid pmc pdf
19. Ning X, Yang Y, Yan H, Zhang J. Anterior chamber depth: a predictor of refractive outcomes after age-related cataract surgery. BMC Ophthalmol 2019;19:134.
crossref pmid pmc pdf
20. Meng J, Wei L, He W, et al. Lens thickness and associated ocular biometric factors among cataract patients in Shanghai. Eye Vis (Lond) 2021;8:22.
crossref pmid pmc pdf
21. Kim JH, Kim M, Lee SJ, et al. Age-related differences in ocular biometry in adult Korean population. BMC Ophthalmol 2016;16:146.
crossref pmid pmc pdf
22. Reitblat O, Gali HE, Chou L, et al. Intraocular lens power calculation in the elderly population using the Kane formula in comparison with existing methods. J Cataract Refract Surg 2020;46:1501-7.
crossref pmid pmc
23. Sella R, Reitblat O, Durnford KM, et al. The effect of patient age on some new and older IOL power calculation formulas. Acta Ophthalmol 2024;102:e696-704.
pmid
24. Norrby S. Sources of error in intraocular lens power calculation. J Cataract Refract Surg 2008;34:368-76.
crossref pmid
25. Hipolito-Fernandes D, Luis ME, Serras-Pereira R, et al. Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison. Br J Ophthalmol 2022;106:349-55.
crossref pmid

Fig. 1
Associations between age and ocular biometric parameters: (A) axial length, (B) anterior chamber depth, and (C) lens thickness. Each dot represents one eye, and solid lines indicate simple linear regression fits. Correlation coefficients and p-values are shown in each panel.
kjo-2026-0085f1.jpg
Table 1
Baseline clinical and ocular characteristics by age group
Variable Total Five age group Binary comparison


≥90 yr 80-89 yr 70-79 yr 60-69 yr <60 yr p-value ≥90 yr <90 yr p-value
Demographic and surgical characteristic
 No. of patients 372 25 67 138 98 44 - 25 347 -
 Sex 0.440 0.838
  Male 171 (46.0) 11 (44.0) 34 (50.7) 60 (43.5) 41 (41.8) 25 (56.8) 11 (44.0) 160 (46.1)
  Female 201 (54.0) 14 (56.0) 33 (49.3) 78 (56.5) 57 (58.2) 19 (43.2) 14 (56.0) 187 (53.9)
 Age (yr) 72.20 ± 11.01 92.76 ± 2.89 83.48 ± 2.65 74.47 ± 2.90 64.64 ± 2.77 53.02 ± 4.49 - 92.76 ± 2.89 70.71 ± 9.84 -
 Anesthesia <0.001 <0.001
  MAC 364 (97.8) 21 (84.0) 66 (98.5) 137 (99.3) 97 (99.0) 43 (97.7) 21 (84.0) 343 (98.8)
  General 8 (2.2) 4 (16.0) 1 (1.5) 1 (0.7) 1 (1.0) 1 (2.3) 4 (16.0) 4 (1.2)
 Laterality 0.573 0.338
  Right 174 (46.8) 14 (56.0) 30 (44.8) 63 (45.7) 50 (51.0) 17 (38.6) 14 (56.0) 160 (46.1)
  Left 198 (53.2) 11 (44.0) 37 (55.2) 75 (54.3) 48 (49.0) 27 (61.4) 11 (44.0) 187 (53.9)
Underlying disease
 HTN 177 (47.6) 17 (68.0) 36 (53.7) 76 (55.1) 37 (37.8) 11 (25.0) <0.001 17 (68.0) 160 (46.1) 0.034
 DM 106 (28.5) 8 (32.0) 19 (28.4) 37 (26.8) 30 (30.6) 12 (27.3) 0.964 8 (32.0) 98 (28.2) 0.688
 CVD 55 (14.8) 4 (16.0) 16 (23.9) 24 (17.4) 9 (9.2) 2 (4.5) 0.024 4 (16.0) 51 (14.7) 0.775
Ocular biometric parameters and visual outcome
 AL (mm) 23.58 ± 1.01 23.30 ± 0.78 23.38 ± 0.81 23.53 ± 1.03 23.60 ± 0.92 24.12 ± 1.32 0.001 23.30 ± 0.78 23.60 ± 1.02 0.079
 Flat K (D) 43.67 ± 1.70 44.10 ± 1.65 43.64 ± 1.61 43.69 ± 1.76 43.79 ± 1.52 43.13 ± 1.97 0.162 44.10 ± 1.65 43.64 ± 1.70 0.191
 Steep K (D) 44.67 ± 1.68 45.20 ± 1.70 44.59 ± 1.58 44.73 ± 1.73 44.69 ± 1.56 44.20 ± 1.86 0.183 45.20 ± 1.70 44.63 ± 1.67 0.117
 Km (D) 44.17 ± 1.63 44.63 ± 1.65 44.11 ± 1.57 44.20 ± 1.68 44.25 ± 1.48 43.72 ± 1.84 0.223 44.63 ± 1.65 44.14 ± 1.63 0.157
 ACD (mm) 3.06 ± 0.43 2.88 ± 0.43 2.96 ± 0.38 2.97 ± 0.43 3.16 ± 0.40 3.36 ± 0.39 <0.001 2.88 ± 0.43 3.07 ± 0.43 0.044
 LT (mm) 4.57 ± 0.47 4.81 ± 0.41 4.77 ± 0.46 4.68 ± 0.42 4.39 ± 0.38 4.21 ± 0.46 <0.001 4.81 ± 0.41 4.55 ± 0.46 0.007
 VA improvement (logMAR)* 0.46 ± 0.59 0.82 ± 0.70 0.53 ± 0.63 0.39 ± 0.56 0.45 ± 0.58 0.40 ± 0.55 0.019 0.82 ± 0.70 0.44 ± 0.58 0.019

Values are presented as number only, number (%), or mean ± standard deviation. p-values were calculated using Pearson chi-square test or Fisher exact test for categorical variables and one-way analysis of variance for continuous variables. VA improvement was defined as preoperative improvement were available in 372 and 364 eyes, respectively.

MAC = monitored anesthesia care; HTN = hypertension; DM = diabetes mellitus; CVD = cerebrovascular disease; AL = axial length; K = keratometry; Km = mean keratometry; ACD = anterior chamber depth; LT = lens thickness; VA = visual acuity.

* Bonferroni-adjusted post hoc comparison showed a significant difference in VA improvement between the 70 79-year and ≥90-year groups( p = 0.013).

Table 2
Refractive PEs by age group and ≥90-year status
Formula Measure Total Five age group* Binary comparison†


≥90 yr 80-89 yr 70-79 yr 60-69 yr‡ <60 yr p-value ≥90 yr <90 yr p-value
Haigis No. of eyes 276 11 50 107 83 25 11 265
PE (D) −0.08 ± 0.65 0.03 ± 0.68 −0.10 ± 0.82 −0.06 ± 0.53 −0.07 ± 0.68 −0.17 ± 0.59 0.917 0.03 ± 0.68 −0.08 ± 0.65 0.603
APE (D) 0.45 ± 0.47 0.49 ± 0.43 0.55 ± 0.62 0.42 ± 0.34 0.44 ± 0.53 0.46 ± 0.40 0.625 0.49 ± 0.43 0.45 ± 0.47 0.770
SRK/T No. of eyes 295 21 52 113 86 23 21 274
PE (D) −0.13 ± 0.65 −0.15 ± 0.57 −0.18 ± 0.89 −0.17 ± 0.52 −0.10 ± 0.69 0.05 ± 0.48 0.612 −0.15 ± 0.57 −0.13 ± 0.65 0.895
APE (D) 0.45 ± 0.48 0.42 ± 0.41 0.58 ± 0.69 0.42 ± 0.34 0.44 ± 0.54 0.36 ± 0.32 0.270 0.42 ± 0.41 0.45 ± 0.49 0.704
Hoffer Q No. of eyes 293 21 51 112 86 23 21 272
PE (D) −0.08 ± 0.66 −0.02 ± 0.61 −0.17 ± 0.89 −0.10 ± 0.53 −0.03 ± 0.71 −0.01 ± 0.49 0.721 −0.02 ± 0.61 −0.08 ± 0.66 0.665
APE (D) 0.47 ± 0.47 0.47 ± 0.37 0.60 ± 0.68 0.42 ± 0.33 0.47 ± 0.52 0.36 ± 0.31 0.187 0.47 ± 0.37 0.47 ± 0.48 0.981
Barrett Universal II No. of eyes 276 12 50 104 83 27 12 264
PE (D) −0.06 ± 0.62 −0.09 ± 0.53 −0.11 ± 0.84 −0.07 ± 0.50 0.00 ± 0.66 −0.12 ± 0.51 0.837 −0.09 ± 0.53 −0.06 ± 0.63 0.846
APE (D) 0.41 ± 0.47 0.38 ± 0.37 0.53 ± 0.66 0.39 ± 0.32 0.38 ± 0.53 0.40 ± 0.33 0.422 0.38 ± 0.37 0.42 ± 0.47 0.747

Values are presented as number only or mean ± standard deviation. For each formula, n indicates the number of eyes with available formula-specific PE and APE data. PE was defined as postoperative spherical equivalent refraction minus formula-predicted refraction, and APE was defined as the absolute value of PE. Bonferroni-adjusted pairwise Wilcoxon signed-rank tests showed that Barrett Universal II had significantly lower APE than SRK/T (p = 0.003) and Hoffer Q (p = 0.001), but not Haigis (p = 0.121). No other pairwise comparisons were statistically significant.

PE = prediction error; D = diopters; APE = absolute prediction error.

* p-values were calculated using one-way analysis of variance for the five-group comparison;

† p-values were calculated using Welch two-sample t-test for the binary comparison between the ≥90-year and <90-year groups;

‡ A significant between-formula difference in APE was observed within the 60- to 69-year group (Friedman test, p < 0.001).

Table 3
Multivariable linear regression analyses for ACD and LT
Coefficient Variable SE p-value
Model 1 (ACD)
 Intercept −3.770 0.876 <0.001
 LT −0.504 0.033 <0.001
 AL 0.250 0.018 <0.001
 Km 0.073 0.011 <0.001
 Age 0.000 0.001 0.774
Model 2 (LT)
 Intercept 4.133 0.446 <0.001
 ACD −0.721 0.048 <0.001
 Age 0.011 0.002 <0.001
 AL 0.079 0.020 <0.001

Values are presented as regression coefficients and standard errors from multivariable linear regression models. Model 1 used ACD as the dependent variable and included LT, AL, Km, and age as independent variables (n = 370). Model 2 used LT as the dependent variable and included ACD, age, and AL as independent variables (n = 372). Analyses were performed using complete cases for the variables included in each model.

ACD = anterior chamber depth; LT = lens thickness; SE = standard error; AL = axial length; Km = mean keratometry.

Table 4
Comparison of PE and APE by LT group
Variable LT <4.57 mm LT ≥4.57 mm p-value


No. of eyes Mean ± SD (D) No. of eyes Mean ± SD (D)
PE
 Haigis 143 −0.19 ± 0.48 133 0.04 ± 0.77 0.004
 SRK/T 151 −0.16 ± 0.50 144 −0.10 ± 0.77 0.410
 Hoffer Q 151 −0.09 ± 0.50 142 −0.07 ± 0.79 0.763
 Barrett Universal II 145 −0.12 ± 0.47 131 0.00 ± 0.76 0.126
APE
 Haigis 143 0.39 ± 0.33 133 0.52 ± 0.57 0.029
 SRK/T 151 0.39 ± 0.35 144 0.51 ± 0.59 0.047
 Hoffer Q 151 0.40 ± 0.32 142 0.54 ± 0.58 0.010
 Barrett Universal II 145 0.36 ± 0.32 131 0.48 ± 0.58 0.032

Values are presented as number only or mean ± standard deviation (SD). p-values were calculated using Welch two-sample t-test. The number of eyes with available PE and APE data is shown for each formula. The 4.57-mm cutoff represents the mean LT of the study cohort and was used as an exploratory threshold. PE was defined as postoperative spherical equivalent refraction minus formula-predicted refraction, and APE was defined as the absolute value of PE.

PE = prediction error; APE = absolute prediction error; LT = lens thickness; D = diopters.

Table 5
Proportions of eyes within specified PE ranges according to LT group
Formula PE range One-eye analysis Bilateral-eye GEE sensitivity analysis


LT <4.57 mm LT ≥4.57 mm p-value* LT <4.57 mm LT ≥4.57 mm OR (95% CI) p-value†
Haigis ±0.25 D 55 / 143 (38.5) 50 / 133 (37.6) 0.981 84 / 225 (37.3) 79 / 212 (37.3) 0.95 (0.62-1.45) 0.852
±0.50 D 103 / 143 (72.0) 80 / 133 (60.2) 0.050 161 / 225 (71.6) 130 / 212 (61.3) 0.63 (0.41-0.97) 0.045
±1.00 D 135 / 143 (94.4) 119 / 133 (89.5) 0.197 209 / 225 (92.9) 190 / 212 (89.6) 0.62 (0.31-1.25) 0.239
±2.00 D 143 / 143 (100) 130 / 133 (97.7) 0.111 225 / 225 (100) 208 / 212 (98.1) NE NE
SRK / T ±0.25 D 71 / 151 (47.0) 54 / 144 (37.5) 0.125 109 / 233 (46.8) 78 / 221 (35.3) 0.62 (0.42-0.92) 0.018
±0.50 D 106 / 151 (70.2) 90 / 144 (62.5) 0.202 167 / 233 (71.7) 138 / 221 (62.4) 0.63 (0.42-0.96) 0.037
±1.00 D 144 / 151 (95.4) 132 / 144 (91.7) 0.291 216 / 233 (92.7) 202 / 221 (91.4) 0.86 (0.41-1.80) 0.686
±2.00 D 151 / 151 (100) 140 / 144 (97.2) 0.056 233 / 233 (100) 216 / 221 (97.7) NE NE
Hoffer Q ±0.25 D 61 / 151 (40.4) 42 / 142 (29.6) 0.069 96 / 232 (41.4) 69 / 220 (31.4) 0.66 (0.44-1.01) 0.052
±0.50 D 111 / 151 (73.5) 92 / 142 (64.8) 0.136 167 / 232 (72.0) 134 / 220 (60.9) 0.60 (0.40-0.90) 0.019
±1.00 D 141 / 151 (93.4) 126 / 142 (88.7) 0.233 215 / 232 (92.7) 198 / 220 (90.0) 0.71 (0.36-1.42) 0.333
±2.00 D 151 / 151 (100) 138 / 142 (97.2) 0.054 232 / 232 (100) 215 / 220 (97.7) NE NE
Barrett Universal II ±0.25 D 65 / 145 (44.8) 50 / 131 (38.2) 0.318 107 / 226 (47.3) 80 / 208 (38.5) 0.71 (0.47-1.07) 0.107
±0.50 D 110 / 145 (75.9) 87 / 131 (66.4) 0.109 171 / 226 (75.7) 138 / 208 (66.3) 0.63 (0.41-0.97) 0.046
±1.00 D 137 / 145 (94.5) 119 / 131 (90.8) 0.351 209 / 226 (92.5) 190 / 208 (91.3) 0.86 (0.42-1.77) 0.678
±2.00 D 145 / 145 (100) 127 / 131 (96.9) 0.050 226 / 226 (100) 203 / 208 (97.6) NE NE

Values are presented as the number of eyes within the specified PE range divided by the number of eyes with available formula-specific PE data (%). ORs compare LT ≥4.57 mm with LT <4.57 mm; an OR below 1 indicates lower odds of achieving the specified PE range in the thicker-lens group. For the ±2.00 D threshold, the odds ratio and p-value were not estimable because all eyes in the LT <4.57 mm group were within the threshold.

PE = prediction error; LT = lens thickness; GEE = generalized estimating equation; OR = odds ratio; CI = confidence interval; D = diopters; NE = not estimable.

* p-values were calculated using the chi-square test with continuity correction or Fisher exact test, as appropriate;

† p-values, ORs, and 95% CIs were obtained from patient-clustered generalized estimating equation logistic models.

Table 6
Multivariable association between continuous LT and refractive PEs
Formula No. of eyes Adjusted LT coefficient (D / mm) 95% CI p-value
PE
 Haigis 276 0.502 0.236 to 0.768 <0.001
 SRK/T 294 0.482 0.235 to 0.730 <0.001
 Hoffer Q 292 0.462 0.210 to 0.713 <0.001
 Barrett Universal II 276 0.312 0.036 to 0.587 0.027
APE
 Haigis 276 0.016 −0.198 to 0.231 0.883
 SRK/T 294 0.046 −0.247 to 0.154 0.650
 Hoffer Q 292 0.021 −0.175 to 0.217 0.832
 Barrett Universal II 276 0.068 −0.145 to 0.282 0.530

Formula-specific multivariable linear regression models included continuous LT, anterior chamber depth, axial length, mean keratometry, and age simultaneously. The n indicates the number of eyes included in each complete-case model. PE was defined as postoperative spherical equivalent refraction minus formula-predicted refraction, and APE was defined as the absolute value of PE.

LT = lens thickness; PE = prediction error; D = diopters; CI = confidence interval; APE = absolute prediction error.



ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
#1001, Jeokseon Hyundai BD
130, Sajik-ro, Jongno-gu, Seoul 03170, Korea
Tel: +82-2-2266-7397    Fax: +82-2-2277-5194    E-mail: kos@ijpnc.com                

Copyright © 2026 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next