The recent evolution in corneal transplantation has provided a more selective replacement of the cornea. Particularly, the use of posterior lamellar keratoplasty (PLK) to replace only the dysfunctional endothelium and Descemet membrane has become a standard treatment for corneal endothelial dysfunction (CED). In previous studies, PLK showed faster recovery, better visual outcome, and better globe stability compared with penetrating keratoplasty. [
1,
2].
The two main techniques used in PLK are Descemet stripping automated endothelial keratoplasty (DSAEK) and Descemet membrane endothelial keratoplasty (DMEK). Although the overall visual outcomes and rejection rates of DSAEK are relatively inferior to those of DMEK [
2,
3], DSAEK remains the most commonly performed technique in PLK [
4]. This may be because DMEK is technically challenging in graft manipulation [
5] and is generally contraindicated in eyes with anatomical abnormalities [
6,
7].
The inferiority in the postoperative visual acuity and rejection rates of DSAEK is mainly because DSAEK grafts are thicker and contain variable degrees of donor stromal tissue in addition to the Descemet membrane and endothelium, compared with DMEK grafts [
8]. Previous studies have suggested that a thinner DSAEK graft minimizes residual stroma and may provide faster visual recovery, better final visual acuity, and less immunologic rejection [
6]. Moreover, one recent study reported that DSAEK using nanothin grafts (50 μm or thinner) provided visual outcomes comparable to those of DMEK [
9]. In this context, using DSAEK grafts to a nanothin degree has become a current trend in performing endothelial keratoplasty in CED patients. However, to the best of our knowledge, no study has been reported regarding nanothin DSAEK in Korean patients. Therefore, this study aimed to evaluate the clinical outcomes of nanothin DSAEK in Korean patients.
Materials and Methods
We conducted a retrospective medical chart review of patients who underwent DSAEK for CED using nanothin grafts (50 μm or thinner) by a single surgeon and followed up for more than one year from July 2019 to October 2021 at the Asan Medical Center. This study was approved by the institutional review board of the Asan Medical Center and the University of Ulsan College of Medicine, Seoul, Korea (No. 2021-0774), and adhered to the tenets outlined in the Declaration of Helsinki. Due to the retrospective nature, the institutional review board of Asan Medical Center waived the need for written informed consent for the study.
Donor graft preparation
The DSAEK grafts were prepared by the Eversight Eye Bank (Chicago, IL, USA). The selection criteria for the donor tissues were as follows: no previous ocular diseases, a minimum corneal endothelial cell density (ECD) of 2,000 cells/mm2, and a maximum time gap of 7 days between donor death and surgery. We ordered the prepared precut grafts to achieve a 40-μm thickness. The grafts were trephined from 8.0 to 8.5 mm in diameter during surgery.
Surgical procedure
All the patients received topical anesthesia with 0.5% proparacaine hydrochloride eye drops (Alcaine; Alcon, Fort Worth, TX, USA). Cataract surgery (cataract extraction and intraocular lens insertion) was performed before DSAEK for patients with cataracts (n = 3, 18.75%). A peripheral side-port incision was made by microvitreoretinal blade (Alcon), through which an anterior chamber maintainer (ACM, Alcon) was introduced. The continuous low flow of balanced salt solution (Alcon) from ACM maintained the anterior chamber. The recipient’s Descemet membrane was stripped with a reversed Sinskey hook (Katena Products, Parsippany-Troy Hills, NJ, USA) via a 4-mm sclero-corneal incision along with an 8.0-mm corneal surface marking. The prepared donor graft was folded over with the endothelial side facing inward and inserted into the anterior ocular chamber with an EndoSerter (Ocular Systems, Winston-Salem, NC, USA) through a 4-mm sclero-corneal incision. After insertion, the graft was then dragged using a reversed Sinskey hook for centering. The ACM was removed, and a 4-mm sclero-corneal incision was sutured and sealed. Sterile air was injected to unfold and attach the graft to the recipient’s stroma. Partial air filling (75% to 80% of the anterior chamber volume) and intraocular pressure (IOP) measurement using a Tono-Pen AVIA tonometer (Reichert, Depew, NY, USA) were performed until a target pressure of 15 to 20 mmHg was achieved. After the patient was maintained in an absolute supine position for at least 3 hours, the graft location and IOP were rechecked using a portable slit-lamp (Kowa American Corporation, New York, NY, USA) and the Tono-Pen AVIA tonometer. The surgeon performed partial air evacuation by anterior chamber paracentesis for increased IOP or rebubbling for graft dislocation. Postoperative medications included topical antibiotics (moxifloxacin 0.5%; Vigamox, Novartis, Tokyo, Japan) and steroid (prednisolone acetate 1%; Pred Forte, Allergan, Westport, Ireland) eye drops four times a day for 1 to 2 months. Thereafter, the administration frequency was gradually reduced until it was discontinued 6 months postoperatively.
Measurements
The following variables were analyzed in each patient: (1) demographic variables (i.e., age, sex, and follow-up duration); (2) ocular characteristics (i.e., preoperative diagnosis and previous history of ocular disorders; (3) donor graft properties (i.e., graft thickness and ECD); (4) surgical procedures; (5) ophthalmologic examinations before surgery and 1, 3, 6, and 12 months after surgery (i.e., best-corrected visual acuity [BCVA] measured by the logarithm of the minimum angle of resolution [logMAR], graft thickness and central corneal thickness [CCT] by anterior segment optical coherence tomography [AS-OCT; Visante OCT, Carl Zeiss, Jena, Germany], and ECD by specular microscopy [CellChek SL, Konan, Nishinomiya, Japan]); and (6) postoperative complications.
Statistical analysis
Descriptive statistics are presented as percentages for categorical variables and as means ± standard deviations for continuous variables. Shapiro-Wilk normality test proved all continuous variables follow a normal distribution (p > 0.05). Repeated measures ANOVA was used to evaluate the differences between preoperative and postoperative variables, including the BCVA, CCT, and ECD. A p-value of <0.05 was used to determine statistical significance. All the statistical analyses were performed using IBM SPSS ver. 21.0 (IBM Corp., Armonk, NY, USA).
Results
Sixteen eyes of 16 patients were included in this study. The demographics and ocular details of the patients are described in
Table 1. The mean age of the patients was 61.18 ± 12.49 years with a female-to-male ratio of 12 : 4. The mean follow-up period was 13.00 ± 0.96 months (range, 12-15 months). The preoperative diagnoses included pseudophakic bullous keratopathy (n = 7, 43.75%), bullous keratopathy of unknown origin (n = 2, 12.50%), pseudoexfoliation syndrome (n = 1, 6.25%), posterior polymorphous corneal dystrophy (n = 1, 6.25%), Herpes endothelitis (n = 1, 6.25%), iridocorneal endothelial syndrome (n = 1, 6.25%), toxic anterior segment syndrome (n = 1, 6.25%), and previous DSAEK graft failure (n = 2, 12.50%). The mean donor graft thickness and graft ECD after precut processing were 47.71 ± 7.91 μm (range, 38.0-68.0 μm) and 2,859.62 ± 228.34 cells/mm
2 (range, 2,545-3,390 cells/mm
2), respectively. It should be noted that measuring graft thickness shortly after the cutting process or surgery may not precisely reflect its actual thickness because the graft is usually in an edematous state at that time. Therefore, we remeasured the graft thickness via AS-OCT at 3 months postoperatively. After deswelling, the average thickness was demonstrated to be 45.25 ± 4.59 μm (range, 38.0-50.0 μm) (
Table 2).
The mean logMAR BCVA improved from 1.37 ± 0.53 preoperatively to 0.68 ± 0.46, 0.55 ± 0.35, 0.40 ± 0.25, and 0.39 ± 0.25 at 1, 3, 6, and 12 months postoperatively (
p = 0.005,
p < 0.001,
p < 0.001, and
p < 0.001), respectively (
Table 3 and
Fig. 1). The mean CCT improved from 752.00 ± 129.11 to 592.57 ± 66.95, 558.38 ± 64.12, 549.67 ± 55.44, and 555.75 ± 54.66 μm at 1, 3, 6, and 12 months postoperatively (
p = 0.007,
p = 0.004,
p = 0.002, and
p = 0.006, respectively) (
Table 4 and
Fig. 2). The mean graft ECD decreased from 2,859.62 ± 228.34 cells/mm
2 preoperatively to 2,069.90 ± 613.75, 1,872.00 ± 644.39, 1,554.16 ± 577.23, and 1,542.25 ± 627.34 cells/mm
2 at 1, 3, 6, and 12 months postoperatively (
p = 0.294,
p = 0.106,
p = 0.015, and
p = 0.012), respectively (
Table 5 and
Fig. 3).
Fig. 4A, 4B show an example of the ophthalmologic examinations before and 12 months after nanothin DSAEK.
The most common adverse event was increased IOP (n = 3, 18.75%), followed by graft dislocation (n = 1, 6.25%). No other adverse events were encountered. All of the increased IOP events were caused by intraoperative air over-filling, resulting in a pupillary block, and successfully controlled with partial air removal by anterior chamber paracentesis. Graft dislocation was also successfully reattached via rebubbling.
Discussion
In this 1-year follow-up study, we demonstrated that nanothin DSAEK provided significant visual acuity improvements without inducing serious adverse events. With respect to visual outcomes, our study showed that nanothin DSAEK provided a mean logMAR BCVA improvement from 1.37 ± 0.53 preoperatively to 0.39 ± 0.25 at 12 months postoperatively. Tourabaly et al. [
10] reported visual outcomes of PLK according to the graft thickness: the mean logMAR BCVA improved from 0.97 to 0.14 after conventional DSAEK (150-250 μm), from 0.84 to 0.14 after thin DSAEK (100-149 μm), from 0.84 to 0.16 after ultra-thin DSAEK (50-99 μm), from 0.85 to 0.11 after nanothin DSAEK (15-49 μm), and from 0.48 to 0.09 after DMEK when followed up for more than 6 months postoperatively. Kurji et al. [
9] also reported that the mean logMAR BCVA improved from 0.32 ± 0.16 to 0.07 ± 0.09 after DSAEK and from 0.33 ± 0.19 to 0.07 ± 0.11 after DMEK at 12 months postoperatively. A recent meta-analysis [
11] found that the 12-month postoperative mean logMAR BCVA of DSAEK was 0.35 (range, 0.2-0.45), whereas that of DMEK was 0.14 logMAR better (95% confidence interval, −0.18 to −0.10). Compared with those previous reports, our nanothin DSAEK resulted in a greater mean BCVA improvement (0.98 logMAR better than baseline BCVA at 12 months postoperatively) than any other types of DSAEK techniques or even DMEK. However, the absolute value of the final BCVA in our patients was not superior to that of other study populations. We assumed that this was because our patients had poorer baseline BCVA than other study populations.
Previous studies reported endothelial cell loss from 32% to 39% at 12 months after conventional DSAEK [
12,
13]. Excessive graft manipulation causing graft trauma has been considered the main cause of lower endothelial cell count, although not significant, in DSAEK-treated eyes versus PKP-treated eyes [
14]. In this study, nanothin DSAEK showed a continuous decrease of ECD during the postoperative follow-up period. The endothelial cell loss became significant at 6 months postoperatively and reached about 50% at 12 months postoperatively, which was greater than that of conventional DSAEK in previous reports. We assumed that it was because the nanothin DSAEK graft is thinner and therefore more difficult to handle than conventional DSAEK graft. This result also suggests that a longer observation period, longer than one year, is needed to evaluate possible additional endothelial cell loss. However, despite the significant postoperative endothelial cell loss, most grafts remained clear without increasing the CCT.
According to a large multicenter retrospective study, the common postoperative complications of conventional DSAEK were graft dislocation (23%), graft failure (18%), graft rejection (6%), and increased IOP (2%) [
15]. Compared with this report, our nanothin DSAEK showed higher prevalence in increased IOP (n = 3, 18.75%) and lower prevalence in graft dislocation (n = 1, 6.25%), all of which were successfully resolved by anterior paracentesis or rebubbling. In addition, there were no other serious complications until 12 months postoperatively. Based upon these results, we assumed that complications of nanothin DSAEK may occur but can be managed by relatively simple procedures. Moreover, in accordance with a previous study [
9], our nanothin DSAEK did not experience immunologic rejection. We support that immunologic rejection in nanothin DSAEK is less likely to occur because the endothelial graft rejection rate is related to the amount of residual stromal tissue. The reported mean endothelial graft rejection rates are approximately 10% in conventional DSAEK [
16], 2.8% in ultra-thin DSAEK [
17], and 0% for both nanothin DSAEK and DMEK [
9].
In this study, the nanothin DSAEK technique was not different from conventional DSAEK, except for the following step: For graft positioning during conventional DSAEK, it is generally recommended to perform complete air filling for 10 minutes with the IOP ranging from 40 to 50 mmHg, followed by removing 20% to 25% of the air [
18]. However, during our nanothin DSAEK, the surgeon performed a partial air-fill only, resulting in successful graft adherence. We assumed that the nanothin DSAEK graft is thinner and therefore lighter than a conventional DSAEK graft, requiring a relatively small amount of buoyance for its adhesion to the recipient cornea.
There are several limitations in this study. First, this study included a small number of patients, resulting in limited statistical power. Second, this study only included patients who underwent nanothin DSAEK; therefore, direct comparisons between nanothin DSAEK and other PLK techniques were not feasible. Third, not all patients underwent the same surgical procedures: some underwent cataract surgery with nanothin DSAEK, but others only received nanothin DSAEK. Ultimately, large-scale comparative studies investigating the clinical outcomes of nanothin DSAEK and thicker DSAEKs and DMEK over a long-term follow-up period are necessary to corroborate the effectiveness of nanothin DSAEK. Nevertheless, this study is meaningful because this is the first study to investigate the surgical outcomes of nanothin DSAEK in Korea.
In conclusion, this 1-year follow-up study showed that nanothin DSAEK produced significant and stable visual improvements without serious postoperative complications. We expect that nanothin DSAEK could be a helpful treatment option for Korean patients with CED.